Skip to content
A

Retaining structures

Where this fits: Docs Atlas › Geotechnical structures › Retaining structures (EN 1997-3 Clause 7)

Embedded walls (sheet pile, combi, diaphragm, secant and contiguous pile, soldier pile), gravity walls (mass concrete, gabion, crib), cantilever walls, abutments, quay walls, cofferdams, and braced or anchored excavations. In the Netherlands, CUR 166 sets the design steps for sheet pile walls. Anchors and groundwater control have their own pages.

sliding, toppling bearing hydraulic heave ground movement embedment Gravity wall Cantilever wall Braced excavation Quay wall its weight holds L-shaped embedded walls, struts anchored sheet pile
Check Limit state Analysis type Usual methods
Rotation or translation of the wall, insufficient embedment ULS (GEO) Stability limit equilibrium (earth pressures), Winkler springs, FEM
Bearing, sliding and toppling of gravity walls ULS (GEO) Stability formulas, limit equilibrium
Vertical equilibrium of the wall ULS (GEO) Stability formulas
Overall stability ULS (GEO) Stability limit equilibrium, FEM
Structural failure of wall, strut or anchor ULS (STR) Deformation Winkler springs, FEM
Hydraulic heave, piping and uplift of the excavation base ULS (HYD, UPL) Groundwater flow formulas, FEM seepage
Wall deflection and ground movement, damage to adjacent buildings SLS Deformation Winkler springs, FEM, empirical (CIRIA C760)
Leakage through or below the wall SLS Groundwater flow FEM seepage
  • Limit equilibrium and formulas: GEO5 Sheeting Design, GEO5 Cantilever Wall, GEO5 Gravity Wall, Oasys Greta, RSWall, WALLAP
  • Winkler springs: D-Sheet Piling, GEO5 Sheeting Check, WALLAP, Oasys Frew
  • Limit analysis: LimitState-GEO, Optum G2, Optum G3
  • FEM and FDM: PLAXIS 2D, PLAXIS 3D, RS2, RS3, GEO5 FEM, Oasys Gofer, ZSoil, MIDAS GTS NX, FLAC, Kratos GeoMechanicsApplication
  • Ground movement and building damage: Oasys Xdisp

Execution standards: EN 12063 (sheet pile walls), EN 1538 (diaphragm walls), EN 1536 (bored pile walls).


Checked 2026-11-13 against EN 1997-1:2004 Section 9 and the EN 1997-3:2025 clause list from secondary sources, not against the EN 1997-3 text.