Skip to content
A

Spread foundations

Where this fits: Docs Atlas › Geotechnical structures › Spread foundations (EN 1997-3 Clause 5)

A spread foundation carries a building’s load onto the ground close to the surface, through a pad, a strip or a raft. Design checks that the ground can carry that load without failing, the ultimate limit states, and without the building settling too much, the serviceability limit states.

groundwater bearing settlement uplift overall stability cyclic load sliding Pad footing Raft Compensated raft Strip footing Gravity base under a column under the whole building basement below groundwater near a slope offshore

You’ll use: effective stress, friction angle, undrained shear strength and bearing capacity. Hover a term for its gist; follow a link only if you need more.

Check Limit state Analysis type Usual methods
Bearing resistance ULS (GEO) Stability formulas, limit analysis, FEM
Sliding ULS (GEO) Stability formulas
Load eccentricity and overturning ULS (EQU, GEO) Stability formulas
Overall stability of a footing near a slope ULS (GEO) Stability limit equilibrium, FEM
Uplift and buoyancy of rafts and basements ULS (UPL) Groundwater flow formulas
Settlement, differential settlement and rotation SLS Deformation formulas, FEM
Heave from swelling or frost SLS Deformation formulas
Vibrations of machine foundations SLS Dynamics formulas (mass-spring), FEM
Learn more: why a footing on clay is checked twice

A saturated clay can’t push its pore water out quickly. Right after the building goes up, the load is carried partly by the water, so the clay behaves undrained and you check bearing with its undrained shear strength.

Over months the water drains, the grains take the load, and the clay behaves drained: you check again with its friction angle and effective stress. For a footing on clay the short-term, undrained case usually governs. For sand, which drains almost at once, only the drained case counts.

Gravity-based foundations, mudmats and suction buckets follow ISO 19901-4 and DNV rather than Eurocode 7. Cyclic loading from waves and wind adds a check: degradation of strength and stiffness under many load cycles.

  • Formulas: D-Foundations, GEO5 Spread Footing, Settle3, GEO5 Settlement, Oasys Pdisp, geofound, groundhog, cecode
  • Limit analysis: GeoEQ Cap, Bearing Bounds, Optum G2, Optum G3, LimitState-GEO
  • FEM: PLAXIS 2D, PLAXIS 3D, RS2, RS3, GEO5 FEM, Oasys Gofer, ZSoil, MIDAS GTS NX, numgeo, Kratos GeoMechanicsApplication
  • Calculation reports: SymEval, our own, for hand calculations a checker can follow

No worked example yet. When a job designs a spread foundation, its worked example is listed here.


Checked 2026-11-13 against EN 1997-1:2004 Section 6 and the EN 1997-3:2025 clause list from secondary sources, not against the EN 1997-3 text.