Spread foundations
Where this fits: Docs Atlas › Geotechnical structures › Spread foundations (EN 1997-3 Clause 5)
A
You’ll use:
What to verify
Section titled “What to verify”| Check | Limit state | Analysis type | Usual methods |
|---|---|---|---|
| Bearing resistance | ULS (GEO) | Stability | formulas, limit analysis, FEM |
| Sliding | ULS (GEO) | Stability | formulas |
| Load eccentricity and overturning | ULS (EQU, GEO) | Stability | formulas |
| Overall stability of a footing near a slope | ULS (GEO) | Stability | limit equilibrium, FEM |
| Uplift and buoyancy of rafts and basements | ULS (UPL) | Groundwater flow | formulas |
| Settlement, differential settlement and rotation | SLS | Deformation | formulas, FEM |
| Heave from swelling or frost | SLS | Deformation | formulas |
| Vibrations of machine foundations | SLS | Dynamics | formulas (mass-spring), FEM |
Learn more: why a footing on clay is checked twice
A saturated clay can’t push its pore water out quickly. Right after the building goes up, the load is carried partly by the water, so the clay behaves undrained and you check bearing with its
Over months the water drains, the grains take the load, and the clay behaves drained: you check again with its
Offshore
Section titled “Offshore”Gravity-based foundations, mudmats and suction buckets follow ISO 19901-4 and DNV rather than Eurocode 7. Cyclic loading from waves and wind adds a check: degradation of strength and stiffness under many load cycles.
Software
Section titled “Software”- Formulas: D-Foundations, GEO5 Spread Footing, Settle3, GEO5 Settlement, Oasys Pdisp, geofound, groundhog, cecode
- Limit analysis: GeoEQ Cap, Bearing Bounds, Optum G2, Optum G3, LimitState-GEO
- FEM: PLAXIS 2D, PLAXIS 3D, RS2, RS3, GEO5 FEM, Oasys Gofer, ZSoil, MIDAS GTS NX, numgeo, Kratos GeoMechanicsApplication
- Calculation reports: SymEval, our own, for hand calculations a checker can follow
Where we did this before
Section titled “Where we did this before”No worked example yet. When a job designs a spread foundation, its worked example is listed here.
Checked 2026-11-13 against EN 1997-1:2004 Section 6 and the EN 1997-3:2025 clause list from secondary sources, not against the EN 1997-3 text.